IPB-5000A – Inverter Power Supply
Inverter Power Unit
Features
- 
Grafic display with color screen
- 
Grafic monitoring functions
- 
Integrated interrupt function welding sequence
- 
Numeral limit monitoring
- 
Quality inspection
- 
Self diagnostic function with error messages
- 
Overcurrent detection
Applications
- 
Insulated wire welding
- 
Spot welding
- 
Thermal cut-off
- 
Resistance soldering and brazing
- 
Resistance welding of small parts
Use
- 
Bidrictional and external data communication
- 
External welding transformer
- 
Small and compact body
- 
Easily integrable in systems
- 
Air cooling
- 
Workpiece control before welding
General
- 
Part Number 811.00 023
- 
Weld Current Type DC inverter
Electrical Power Supply
- Supply Voltage 3-phase, 200-240V or 380-480V
- Mains Frequency 50 or 60 Hz
Power Data
- 
Inverter Frequency 5 kHz
- 
Max. Weld Current 6 kA
- 
Max. Weld Period 2 x 500 ms
- 
Functions
- 
Control / Control Mode Constant secondary current and voltage, combination of both, constant power
- 
Programmable Weld Schedules 127
- 
External Weld Schedules Selection 127; with and without parity
- 
No. of Weld Pulses 2
- 
Weld Pulse Control Squeeze time, resistance precheck, upslope, welding pulse 1 and 2,
 downslope, cooling time, hold time
- 
Counter Output signal when presettings are reached:
 Total counter, good product counter, work piece counter
- 
Up-Slope Time with / without
 2 / 3
Setting Ranges
- 
Current range 0.2 – 2 kA; 0.4 – 4 kA; 0.6 – 6 kA (dependent on weld transformer)
- 
Voltage Range 0.30 – 9.99 V
- 
Power range 0.2 – 20 kW
- 
Signal Processing No Good: to choice break or make contact
- 
Output Signal Activation 10 / 100 ms; auomatically or until start signal becomes inactive
- 
Counter Default 000000 – 999999
Time Settings
- 
Squeeze Time 0000 – 9999 ms
- 
Resistance Checking 0.00 – 9.99 ms
- 
Up-Slope Time Upslope 1 and 2: 000.0 – 500.0 ms
- 
Start Signal Stabilisation Time Presetting: 1 – 5 – 10 – 20 ms
- 
Weld Pulse Pulse 1 and 2: 000,0 – 500,0 ms
- 
Delay Time after end of welding current to monitoring of penetration
- 
Down-slope Time Downslope 1 and 2: 000.0 – 500.0 ms
- 
Hold Time after downslope: 0 – 999 ms
- 
Cooling Period between pulse 1 and 2: 00.0 – 99.8
Distance Measurement
- 
Displacement Measuring Range max. 30 mm
- 
Penetration Lower and upper limit of numeral penetration after
 welding from +29,999 to -29,999 mm
- 
Penetration Measurement Accuracy Resolution of diplacement sensor: 1 μm
Monitoring Functions
- 
Measured Parameters Pulse width, weld time, penetration, current, voltage, resistance
- 
Limit Values Lower and upper limit of current, voltage, power, penetration
- 
Part Detection Before welding: Work piece available resp. Electrode
 in accordance to limit window (+29,999 bis -29,999 mm)
- 
Weld Abort Jump when presetted penetration is reached:
 1st pulse to cooling time, 2nd pulse to hold time
- 
Numeral Limits Current, voltage, power, resistance, weld time, penetration
- 
Graphic Limits Current or voltage; power, resistance, penetration
- 
Envelope Waveform Grafic monitoring of a value
- 
Up-Slope with or without monitoring
- 
Weld Current Monitoring delay time 00 – 10 ms
Interfaces
- 
Serial Interface RS232 or RS 485
Mechanical Data
- 
Dimensions 269 x 172 x 390 (H x W x D)
- 
Weight 15 kg
Operation Data
- 
Ambient Temperature 5 – 40° C
- 
Humidity < 90% (no condensation)
- 
Cooling air-cooled
Transformer
- 
Weld Transformer external
- 
Transformer Type e.g. ITB-780A6
Accessory
- 
Penetration Sensor all as an option: GS-1630A (Ono Sokki); GS-1631A (Ono Sokki);
 with conversion cable: (Mitutoyo); ST-1278 (Heidenhain)
- 
3 / 3